Project description:ObjectiveTo evaluate the effects of early treatment with continuous positive airway pressure (CPAP) on nutritional intake and in-hospital growth rates of extremely preterm (EPT) infants.Study designEPT infants (240/7-276/7 weeks of gestation) enrolled in the Surfactant Positive Airway Pressure and Pulse Oximetry Trial (SUPPORT) were included. EPT infants who died before 36 weeks of postmenstrual age (PMA) were excluded. The growth rates from birth to 36 weeks of PMA and follow-up outcomes at 18-22 months corrected age of EPT infants randomized at birth to either early CPAP (intervention group) or early intubation for surfactant administration (control group) were analyzed.ResultsGrowth data were analyzed for 810 of 1316 infants enrolled in SUPPORT (414 in the intervention group, 396 in the control group). The median gestational age was 26 weeks, and the mean birth weight was 839 g. Baseline characteristics, total nutritional intake, and in-hospital comorbidities were not significantly different between the 2 groups. In a regression model, growth rates between birth and 36 weeks of PMA, as well as growth rates during multiple intervals from birth to day 7, days 7-14, days 14-21, days 21-28, day 28 to 32 weeks PMA, and 32-36 weeks PMA did not differ between treatment groups. Independent of treatment group, higher growth rates from day 21 to day 28 were associated with a lower risk of having a Bayley-III cognitive score <85 at 18-22 months corrected age (P = .002).ConclusionsEPT infants randomized to early CPAP did not have higher in-hospital growth rates than infants randomized to early intubation.
Project description:BackgroundExtremely preterm infants are often exposed to endotracheal tube continuous positive airway pressure (ETT-CPAP) trials to assess extubation readiness. The effects of ETT-CPAP trial on their diaphragmatic activity (Edi) and breathing variability is unknown.MethodsProspective observational study enrolling infants with birth weight ≤1250 g undergoing their first extubation attempt. Diaphragmatic activity, expressed as the absolute minimum (Edi min) and maximum values (Edi max), area under the Edi signal, and breath-by-breath analyses for breath areas, amplitudes, widths, and neural inspiratory and expiratory times, were analyzed during mechanical ventilation (MV) and ETT-CPAP. Neural breathing variability of each of these parameters was also calculated and compared between MV and ETT-CPAP.ResultsThirteen infants with median (interquartile range) birth weight of 800 g [610-920] and gestational age of 25.4 weeks [24.4-26.3] were included. Diaphragmatic activity significantly increased during ETT-CPAP when compared to MV:Edi max (44.2 vs. 38.1 μV), breath area (449 vs. 312 μV·s), and amplitude (10.12 vs. 7.46 μV). Neural breathing variability during ETT-CPAP was characterized by increased variability for amplitude and area under the breath, and decreased for breath time and width.ConclusionsA 5-min ETT-CPAP in extremely preterm infants undergoing extubation imposed significant respiratory load with changes in respiratory variability.ImpactETT-CPAP trials are often used to assess extubation readiness in extremely preterm infants, but its effects upon their respiratory system are not well known. Diaphragmatic activity analysis demonstrated that these infants are able to mount an important response to a short trial. A 5-min trial imposed a significant respiratory load evidenced by increased diaphragmatic activity and changes in breathing variability. Differences in breathing variability were observed between successful and failed extubations, which should be explored further in extubation readiness investigations. This type of trial cannot be recommended for preterm infants in clinical practice until clear standards and accuracy are established.
Project description:ObjectiveTo test the hypothesis that infants born <30 weeks' gestation supported by Seattle-PAP will have lower rates of continuous positive airway pressure (CPAP) failure than infants supported with conventional, Fisher&Paykel-CPAP (FP-CPAP).Study designRandomized trial (3/2017-01/2019) at 5 NICUs. The primary outcome was CPAP failure; subgroup analyses (gestational age, receipt antenatal corticosteroids) were performed.ResultsA total of 232 infants were randomized. Infants in the Seattle-PAP and FP-CPAP groups had mean gestational ages of 27.0 and 27.2 weeks, respectively. We observed no differences in rates of treatment failure between Seattle-PAP (40/112, 35.7%) and FP-CPAP (38/120, 31.7%; risk difference, 4.1%; 95% CI, -8.1-16.2; P = 0.51). Subgroup analysis indicated no differences in rates of CPAP failure. We observed no differences between the two groups in frequencies of adverse events or duration of respiratory support.ConclusionsAmong infants born <30 weeks' gestation, rates of CPAP failure did not differ between Seattle-PAP and FP-CPAP.
Project description:BackgroundContinuous positive airway pressure (CPAP) is widely used in preterm infants. Identification of readiness for weaning from CPAP can balance benefits with risks of CPAP exposure. We tested the hypothesis that preterm infants that successfully transition off CPAP have higher oxygen saturations prior to weaning compared with infants who fail weaning from CPAP.MethodsThis was a single-center-matched case-control study in infants ≤30 weeks' gestation receiving ≤30% FiO2 weaned off CPAP during the first postnatal week. Cases were infants placed back on CPAP within 7 days of being taken off CPAP, whereas control infants remained off CPAP for 7 consecutive days following CPAP discontinuation. Infants were matched on gestational age at birth (±10 days). Prospectively collected histograms detailing the distribution of oxygen saturations prior to CPAP discontinuation were compared between cases and controls.ResultsOver a 12-month monitoring period, 36 infants met inclusion criteria. Baseline characteristics, morbidities, and clinical variables did not differ between cases and controls. Controls achieved oxygen saturations of 95-97 and 97-100% for longer duration compared to cases (p < 0.05).ConclusionsIn preterm infants with RDS receiving CPAP and ≤30% FiO2, infants with higher oxygen saturations had greater success in transitioning off CPAP.
Project description:BackgroundNasal masks and nasal prongs are used as interfaces for providing continuous positive airway pressure (CPAP) for preterm infants with or at risk of respiratory distress, either as primary support after birth or as ongoing support after endotracheal extubation from mechanical ventilation. It is unclear which type of interface is associated with lower rates of CPAP treatment failure, nasal trauma, or mortality and other morbidity.ObjectivesTo assess the benefits and harms of nasal masks versus nasal prongs for reducing CPAP treatment failure, nasal trauma, or mortality and other morbidity in newborn preterm infants with or at risk of respiratory distress.Search methodsWe used standard, extensive Cochrane search methods. The latest search date was October 2021.Selection criteriaWe included randomised controlled trials comparing masks versus prongs as interfaces for delivery of nasal CPAP in newborn preterm infants (less than 37 weeks' gestation) with or at risk of respiratory distress.Data collection and analysisWe used standard Cochrane methods. Our primary outcomes were 1. treatment failure, 2. all-cause mortality, and 3. neurodevelopmental impairment. Our secondary outcomes were 4. pneumothorax, 5. moderate-severe nasal trauma, 6. bronchopulmonary dysplasia, 7. duration of CPAP use, 8. duration of oxygen supplementation, 9. duration of hospitalisation, 10. patent ductus arteriosus receiving medical or surgical treatment, 11. necrotising enterocolitis, 12. severe intraventricular haemorrhage, and 13. severe retinopathy of prematurity. We used the GRADE approach to assess the certainty of the evidence.Main resultsWe included 12 trials with 1604 infants. All trials were small (median number of participants 118). The trials occurred after 2001 in care facilities internationally, predominantly in India (eight trials). Most participants were preterm infants of 26 to 34 weeks' gestation who received nasal CPAP as the primary form of respiratory support after birth. The studied interfaces included commonly used commercially available masks and prongs. Lack of measures to blind caregivers or investigators was a potential source of performance and detection bias in all the trials. Meta-analyses suggested that use of masks compared with prongs may reduce CPAP treatment failure (risk ratio (RR) 0.72, 95% confidence interval (CI) 0.58 to 0.90; 8 trials, 919 infants; low certainty). The type of interface may not affect mortality prior to hospital discharge (RR 0.83, 95% CI 0.56 to 1.22; 7 trials, 814 infants; low certainty). There are no data on neurodevelopmental impairment. Meta-analyses suggest that the choice of interface may result in little or no difference in the risk of pneumothorax (RR 0.93, 95% CI 0.45 to 1.93; 5 trials, 625 infants; low certainty). Use of masks rather than prongs may reduce the risk of moderate-severe nasal injury (RR 0.55, 95% CI 0.44 to 0.71; 10 trials, 1058 infants; low certainty). The evidence is very uncertain about the effect on bronchopulmonary dysplasia (RR 0.69, 95% CI 0.46 to 1.03; 7 trials, 843 infants; very low certainty).Authors' conclusionsThe available trial data provide low-certainty evidence that use of masks compared with prongs as the nasal CPAP interface may reduce treatment failure and nasal injury, and may have little or no effect on mortality or the risk of pneumothorax in newborn preterm infants with or at risk of respiratory distress. The effect on bronchopulmonary dysplasia is very uncertain. Large, high-quality trials would be needed to provide evidence of sufficient validity and applicability to inform policy and practice.
Project description:ObjectivesThe current clinical treatment of neonates with respiratory distress syndrome includes endotracheal intubation and intratracheal instillation of exogenous surfactant. Nebulization of surfactant offers an attractive alternative. The aims of this study were to test nebulization as a noninvasive method of administering surfactant and determine the optimal dose for the treatment of respiratory distress syndrome-associated pathophysiology of the neonatal lungs.DesignProspective, randomized, animal model study.SettingAn experimental laboratory.SubjectsThirty-six newborn piglets.InterventionsDifferent doses (100, 200, 400, and 600 mg/kg) of poractant alfa were administered via a vibrating membrane nebulizer (eFlow-Neos; Pari Pharma GmbH, Starnberg, Germany) or a bolus administration using the intubation-surfactant-extubation (Insure) technique (200 mg/kg) to spontaneously breathing newborn piglets (n = 6/group) with bronchoalveolar lavage-induced respiratory distress syndrome during nasal continuous positive airway pressure (180 min).Measurements and main resultsPulmonary, hemodynamic, and cerebral effects were assessed. Histologic analysis of lung and brain tissue was also performed. After repeated bronchoalveolar lavage, newborn piglets developed severe respiratory distress syndrome. Rapid improvement in pulmonary status was observed in the Insure group, whereas a dose-response effect was observed in nebulized surfactant groups. Nebulized poractant alfa was more effective at doses higher than 100 mg/kg and was associated with similar pulmonary, hemodynamic, and cerebral behavior to that in the Insure group, but improved lung injury scores.ConclusionsIn newborn piglets with severe bronchoalveolar lavage-induced respiratory distress syndrome, our results demonstrate that the administration of nebulized poractant alfa using an investigational customized eFlow-Neos nebulizer is an effective and safe noninvasive surfactant administration technique.
Project description:The treatment of choice for obstructive sleep apnoea (OSA) is continuous positive airway pressure therapy (CPAP). Since its introduction in clinical practice, CPAP has been used in various clinical conditions with variable and heterogeneous outcomes. In addition to the well-known effects on the upper airway CPAP impacts on intrathoracic pressures, haemodynamics and blood pressure (BP) control. However, short- and long-term effects of CPAP therapy depend on multiple variables which include symptoms, underlying condition, pressure used, treatment acceptance, compliance and usage. CPAP can alter long-term cardiovascular risk in patients with cardiorespiratory conditions. Furthermore, the effect of CPAP on the awake patient differs from the effect on the patients while asleep, and this might contribute to discomfort and removal of the use interface. The purpose of this review is to highlight the physiological impact of CPAP on the cardiorespiratory system, including short-term benefits and long-term outcomes.
Project description:To determine the early factors associated with continuous positive airway pressure (CPAP) failure in moderate-to-late preterm infants (32 + 0/7 to 36 + 6/7 weeks' gestation) from the NEOBS cohort study. The NEOBS study was a multi-center, prospective, observational study in 46 neonatal intensive care units in France, which included preterm and late preterm infants with early neonatal respiratory distress. This analysis included a subset of the NEOBS population who had respiratory distress and required ventilatory support with CPAP within the first 24 h of life. CPAP failure was defined as the need for tracheal intubation within 72 h of CPAP initiation. Maternal and neonatal clinical parameters in the delivery room and clinical data at 3 h of life were analyzed. CPAP failure occurred in 45/375 infants (12%), and compared with infants with CPAP success, they were mostly singletons (82.2% vs. 62.1%; p < 0.01), had a lower Apgar score at 10 min of life (9.1 ± 1.3 vs. 9.6 ± 0.8; p = 0.02), and required a higher fraction of inspired oxygen (FiO2; 34.4 ± 15.9% vs. 22.8 ± 4.1%; p < 0.0001) and a higher FiO2*positive end-expiratory pressure (PEEP) (1.8 ± 0.9 vs. 1.1 ± 0.3; p < 0.0001) at 3 h. FiO2 value of 0.23 (R2 = 0.73) and FiO2*PEEP of 1.50 (R2 = 0.75) best predicted CPAP failure. The risk of respiratory distress and early CPAP failure decreased 0.7 times per 1-week increase in gestational age and increased 1.7 times with every one-point decrease in Apgar score at 10 min and 19 times with FiO2*PEEP > 1.50 (vs. ≤ 1.50) at 3 h (R2 of the overall model = 0.83). Conclusion: In moderate-to-late preterm infants, the combination of singleton pregnancy, lower Apgar score at 10 min, and FiO2*PEEP > 1.50 at 3 h can predict early CPAP failure with increased accuracy. What is Known: •Respiratory distress syndrome (RSD) represents an unmet medical need in moderate-to-late preterm births and is commonly treated with continuous positive airway pressure (CPAP) to reduce mortality and the need for additional ventilatory support. • Optimal management of RSD is yet to be established, with several studies suggesting that identification of predictive factors for CPAP failure can aid in the prompt treatment of infants likely to experience this failure. What is New: •Secondary analysis of the observational NEOBS study indicated that oxygen requirements during CPAP therapy, especially the product of fraction of inspired oxygen (FiO2) and positive end-expiratory pressure (PEEP), are important factors associated with early CPAP failure in moderate-to-late term preterm infants. •The combination of a singleton pregnancy, low Apgar score at 10 minutes, and high FiO2*PEEP at 3 hours can predict early CPAP failure with increased accuracy, highlighting important areas for future research into the prevention of CPAP failure.
Project description:IntroductionRespiratory distress syndrome (RDS) or surfactant deficiency occurs primarily in premature infants resulting in composite outcomes of death or bronchopulmonary dysplasia. Initial management strategies for preterm infants with RDS includes early initiation of continuous positive airway pressure (CPAP) and titration of fractional inspired oxygen (FiO2), and may include the use of less invasive surfactant administration (LISA) to avoid the need for mechanical ventilation. In order to optimise success of non-invasive support, the use of early caffeine therapy may be critical to the success of LISA. The objective of our trial is to evaluate whether infants that receive early caffeine, CPAP and surfactant via the LISA method compared with infants that receive caffeine and CPAP alone, have a decreased need for invasive mechanical ventilation in the first 72 hours of life.Methods and analysisCaLI is an unblinded multicentre, randomised controlled, trial of 180 preterm infants (24+0-29+6 weeks corrected GA). Criteria for intubation/treatment failure will follow guidelines for the management of RDS, including: (1) CPAP level of 6-8 cmH20 and FiO2 >0.40 required to maintain saturations 90%-95% for 2 hours after randomisation; (2) a pH of 7.15 or less or a paCO2 >65 mm Hg on any (2) blood gases (arterial/capillary/or venous) at least 2 hours after randomisation and in the first 72 hours of life; (3) continued apnoea/bradycardia/desaturation events despite nasal intermittent minute ventilation mode of ventilation. Infants will be randomised by 1 hour of life and caffeine/LISA treatments administered by 2 hour of life. Caffeine will be administered prior to surfactant in the LISA arm and before 2 hours of life in the control arm.Ethics and disseminationChiesi Farmaceutici, S.p.A is the sponsor of CaLI. Ethical approval has been obtained. Results will be submitted for publication in peer reviewed journals.Trial registration numberwww.Clinicaltrials.gov: NCT04209946; Pre-results.