On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.


ABSTRACT:

Purpose

To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners.

Methods

Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points.

Results

The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %.

Conclusion

Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach.

SUBMITTER: Chen KT 

PROVIDER: S-EPMC5285302 | biostudies-literature | 2017 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

Chen Kevin T KT   Izquierdo-Garcia David D   Poynton Clare B CB   Chonde Daniel B DB   Catana Ciprian C  

European journal of nuclear medicine and molecular imaging 20160829 3


<h4>Purpose</h4>To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners.<h4>Methods</h4>Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the pri  ...[more]

Similar Datasets

| S-EPMC4502321 | biostudies-literature
| S-EPMC9529893 | biostudies-literature
| S-EPMC6779234 | biostudies-literature
| S-EPMC9606046 | biostudies-literature
| S-EPMC6196145 | biostudies-literature
| S-EPMC4891225 | biostudies-literature
| S-EPMC7269241 | biostudies-literature
| S-EPMC5843521 | biostudies-literature
| S-EPMC3477199 | biostudies-other
| S-EPMC4090355 | biostudies-other