Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy.


ABSTRACT: Aim:Determine the 1) effectiveness of correction for gradient-non-linearity and susceptibility effects on both QUASAR GRID3D and CIRS phantoms; and 2) the magnitude and location of regions of residual distortion before and after correction. Background:Using magnetic resonance imaging (MRI) as a primary dataset for radiotherapy planning requires correction for geometrical distortion and non-uniform intensity. Materials and Methods:Phantom Study: MRI, computed tomography (CT) and cone beam CT images of QUASAR GRID3D and CIRS head phantoms were acquired. Patient Study: Ten patients were MRI-scanned for stereotactic radiosurgery treatment. Correction algorithm: Two magnitude and one phase difference image were acquired to create a field map. A MATLAB program was used to calculate geometrical distortion in the frequency encoding direction, and 3D interpolation was applied to resize it to match 3D T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) images. MPRAGE images were warped according to the interpolated field map in the frequency encoding direction. The corrected and uncorrected MRI images were fused, deformable registered, and a difference distortion map generated. Results:Maximum deviation improvements: GRID3D , 0.27 mm y-direction, 0.07 mm z-direction, 0.23 mm x-direction. CIRS, 0.34 mm, 0.1 mm and 0.09 mm at 20-, 40- and 60-mm diameters from the isocenter. Patient data show corrections from 0.2 to 1.2 mm, based on location. The most-distorted areas are around air cavities, e.g. sinuses. Conclusions:The phantom data show the validity of our fast distortion correction algorithm. Patient-specific data are acquired in <2 min and analyzed and available for planning in less than a minute.

SUBMITTER: Bagherimofidi SM 

PROVIDER: S-EPMC6807066 | biostudies-literature | 2019 Nov-Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy.

Bagherimofidi Seyed Mehdi SM   Yang Claus Chunli CC   Rey-Dios Roberto R   Kanakamedala Madhava R MR   Fatemi Ali A  

Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 20191019 6


<h4>Aim</h4>Determine the 1) effectiveness of correction for gradient-non-linearity and susceptibility effects on both QUASAR GRID<sup>3D</sup> and CIRS phantoms; and 2) the magnitude and location of regions of residual distortion before and after correction.<h4>Background</h4>Using magnetic resonance imaging (MRI) as a primary dataset for radiotherapy planning requires correction for geometrical distortion and non-uniform intensity.<h4>Materials and methods</h4><b>Phantom Study:</b> MRI, comput  ...[more]

Similar Datasets

| S-EPMC7807620 | biostudies-literature
| S-EPMC7607582 | biostudies-literature
| S-EPMC10106483 | biostudies-literature
| S-EPMC7807542 | biostudies-literature
| S-EPMC5429659 | biostudies-literature
| S-EPMC5013753 | biostudies-literature
| S-EPMC8955512 | biostudies-literature
| S-EPMC10113900 | biostudies-literature
| S-EPMC9692033 | biostudies-literature
| S-EPMC8058029 | biostudies-literature