Project description:BackgroundAn increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to track CI changes. This study investigates whether changes in CD peak velocity (CDPV) and corrected flow time (cFT) during an EEOt were correlated with CI changes and if CDPV and cFT changes predicted fluid responsiveness in patients with septic shock.MethodsProspective, single-center study in adults with hemodynamic instability. The CDPV and cFT on carotid artery Doppler and hemodynamic variables from the pulse contour analysis EV1000™ were recorded at baseline, during a 20-s EEOt, and after fluid challenge (500 mL). We defined responders as those who increased CI ≥ 15% after a fluid challenge.ResultsWe performed 44 measurements in 18 mechanically ventilated patients with septic shock and without arrhythmias. The fluid responsiveness rate was 43.2%. The changes in CDPV were significantly correlated with changes in CI during EEOt (r = 0.51 [0.26-0.71]). A significant, albeit lower correlation, was found for cFT (r = 0.35 [0.1-0.58]). An increase in CI ≥ 5.35% during EEOt predicted fluid responsiveness with 78.9% sensitivity and 91.7% specificity, with an area under the ROC curve (AUROC) of 0.85. An increase in CDPV ≥ 10.5% during an EEOt predicted fluid responsiveness with 96.2% specificity and 53.0% sensitivity with an AUROC of 0.74. Sixty-one percent of CDPV measurements (from - 13.5 to 9.5 cm/s) fell within the gray zone. The cFT changes during EEOt did not accurately predict fluid responsiveness.ConclusionsIn septic shock patients without arrhythmias, an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler combined with EEOt may help optimize preload when invasive hemodynamic monitoring is unavailable. However, the 61% gray zone is a major limitation (retrospectively registered on Clinicaltrials.gov NCT04470856 on July 14, 2020).
Project description:We evaluated the pulmonary effects of two ventilator-driven alveolar recruitment maneuver (ARM) methods during laparoscopic surgery. Sixty-four patients undergoing robotic prostatectomy were randomized into two groups: incrementally increasing positive end-expiratory pressure in a stepwise manner (PEEP group) versus tidal volume (VT group). We performed each ARM after induction of anesthesia in the supine position (T1), after pneumoperitoneum in the Trendelenburg position (T2), and after peritoneum desufflation in the supine position (T3). The primary outcome was change in end-expiratory lung impedance (EELI) before and 5 min after ARM at T3, measured by electrical impedance tomography. The PEEP group showed significantly higher increasing EELI 5 min after ARM than the VT group at T1 and T3 (median [IQR] 460 [180,800] vs. 200 [80,315], p = 0.002 and 280 [170,420] vs. 95 [55,175], p = 0.004, respectively; PEEP group vs. VT group). The PEEP group showed significantly higher lung compliance and lower driving pressure at T1 and T3. However, there was no significant difference in EELI change, lung compliance, or driving pressure after ARM at T2. The ventilator-driven ARM by the increasing PEEP method led to greater improvements in lung compliance at the end of laparoscopic surgery than the increasing VT method.
Project description:BackgroundPositive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury.ObjectivesTo evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation.Methods5-12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers.ResultsAlteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation.ConclusionsSigns of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide the frequency of recruitment maneuvers to help ameloriate ventilator-induced lung injury.
Project description:BACKGROUND:We performed a systematic review and meta-analysis of studies assessing the end-expiratory occlusion test (EEXPO test)-induced changes in cardiac output (CO) measured by any haemodynamic monitoring device, as indicators of preload responsiveness. METHODS:MEDLINE, EMBASE and Cochrane Database were screened for original articles. Bivariate random-effects meta-analysis determined the Area under the Summary Receiver Operating Characteristic (AUSROC) curve of EEXPO test-induced changes in CO to detect preload responsiveness, as well as pooled sensitivity and specificity and the best diagnostic threshold. RESULTS:Thirteen studies (530 patients) were included. Nine studies were performed in the intensive care unit and four in the operating room. The pooled sensitivity and the pooled specificity for the EEXPO test-induced changes in CO were 0.85 [0.77-0.91] and 0.88 [0.83-0.91], respectively. The AUSROC curve was 0.91 [0.86-0.94] with the best threshold of CO increase at 5.1 ± 0.2%. The accuracy of the test was not different when changes in CO were monitored through pulse contour analysis compared to other methods (AUSROC: 0.93 [0.91-0.95] vs. 0.87 [0.82-0.96], respectively, p = 0.62). Also, it was not different in studies in which the tidal volume was ≤ 7 mL/kg compared to the remaining ones (AUSROC: 0.96 [0.92-0.97] vs. 0.89 [0.82-0.95] respectively, p = 0.44). Subgroup analyses identified one possible source of heterogeneity. CONCLUSIONS:EEXPO test-induced changes in CO reliably detect preload responsiveness. The diagnostic performance is not influenced by the method used to track the EEXPO test-induced changes in CO. Trial registration The study protocol was prospectively registered on PROSPERO: CRD42019138265.
Project description:BackgroundThe aim of this study was to evaluate whether a 20-second end-expiratory occlusion (EEO) test can predict fluid responsiveness in cardiac surgery patients in the operating theatre.MethodsThis prospective study enrolled 75 mechanically ventilated patients undergoing elective coronary artery bypass grafting surgery. Hemodynamic data coupled with transesophageal echocardiography monitoring of the velocity time integral (VTI) and the peak velocity (Vmax) at the left ventricular outflow tract were collected at each step (baseline 1, EEO, baseline 2 and fluid challenge). Patients were divided into fluid responders (increase in VTI ≥15%) and non-responders (increase in VTI <15%) after a fluid challenge (6 mL 0.9% saline per kg, given in 10 minutes).ResultsFluid challenge significantly increased the VTI by more than 15% in 36 (48%) patients (responders). An increase in VTI greater than 5% during the EEO test predicted fluid responsiveness with a sensitivity of 81% and a specificity of 93%. The area under the receiver-operating characteristic curve (AUROC) of ΔVTI-EEO was 0.90 [95% confidence interval (CI): 0.83-0.97]. ΔVmax-EEO was poorly predictive of fluid responsiveness, with an AUC of 0.75 (95% CI: 0.63-0.86).ConclusionsChanges in VTI induced by a 20-second EEO can reliably predict fluid responsiveness in cardiac surgical patients in the operating theatre, whereas the changes in Vmax cannot.
Project description:BackgroundEsophageal pressure is used as a reliable surrogate of the pleural pressure. It is conventionally measured by an esophageal balloon placed in the lower part of the esophagus. To validate the correct position of the balloon, a positive pressure occlusion test by compressing the thorax during an end-expiratory pause or a Baydur test obtained by occluding the airway during an inspiratory effort is used. An acceptable catheter position is defined when the ratio between the changes in esophageal and airway pressure (∆Pes/∆Paw) is close to unity. Sedation and paralysis could affect the accuracy of esophageal pressure measurements. The aim of this study was to evaluate, in mechanically ventilated patients, the effects of paralysis, two different esophageal balloon positions and two PEEP levels on the ∆Pes/∆Paw ratio measured by the positive pressure occlusion and the Baydur tests and on the end-expiratory esophageal pressure and respiratory mechanics (lung and chest wall).MethodsTwenty-one intubated and mechanically ventilated patients (mean age 64.8 ± 14.0 years, body mass index 24.2 ± 4.3 kg/m(2), PaO2/FiO2 319.4 ± 117.3 mmHg) were enrolled. In step 1, patients were sedated and paralyzed during volume-controlled ventilation, and in step 2, they were only sedated during pressure support ventilation. In each step, two esophageal balloon positions (middle and low, between 25-30 cm and 40-45 cm from the mouth) and two levels of PEEP (0 and 10 cmH2O) were applied. The ∆Pes/∆Paw ratio and end-expiratory esophageal pressure were evaluated.ResultsThe ∆Pes/∆Paw ratio was slightly higher (+0.11) with positive occlusion test compared with Baydur's test. The level of PEEP and the esophageal balloon position did not affect this ratio. The ∆Pes and ∆Paw were significantly related to a correlation coefficient of r = 0.984 during the Baydur test and r = 0.909 in the positive occlusion test. End-expiratory esophageal pressure was significantly higher in sedated and paralyzed patients compared with sedated patients (+2.47 cmH2O) and when esophageal balloon was positioned in the low position (+2.26 cmH2O). The esophageal balloon position slightly influenced the lung elastance, while the PEEP reduced the chest wall elastance without affecting the lung and total respiratory system elastance.ConclusionsParalysis and balloon position did not clinically affect the measurement of the ∆Pes/∆Paw ratio, while they significantly increased the end-expiratory esophageal pressure.
Project description:BackgroundCharacterizing patient-ventilator interaction in critically ill patients is time-consuming and requires trained staff to evaluate the behavior of the ventilated patient.MethodsIn this study, we recorded surface electromyography ([Formula: see text]) signals from the diaphragm and intercostal muscles and esophageal pressure ([Formula: see text]) in mechanically ventilated patients with ARDS. The sEMG recordings were preprocessed, and two different algorithms (triangle algorithm and adaptive thresholding algorithm) were used to automatically detect inspiratory patient effort. Based on the detected inspirations, major asynchronies (ineffective, auto-, and double triggers and double efforts), delayed and synchronous triggers were computationally classified. Reverse triggers were not considered in this study. Subsequently, asynchrony indices were calculated. For the validation of detected efforts, two experts manually annotated inspiratory patient activity in [Formula: see text], blinded toward each other, the [Formula: see text] signals, and the algorithmic results. We also classified patient-ventilator interaction and calculated asynchrony indices with manually detected inspirations in [Formula: see text] as a reference for automated asynchrony classification and asynchrony index calculation.ResultsSpontaneous breathing activity was recognized in 22 out of the 36 patients included in the study. Evaluation of the accuracy of the algorithms using 3057 inspiratory efforts in [Formula: see text] demonstrated reliable detection performance for both methods. Across all datasets, we found a high sensitivity (triangle algorithm/adaptive thresholding algorithm: 0.93/0.97) and a high positive predictive value (0.94/0.89) against expert annotations in [Formula: see text]. The average delay of automatically detected inspiratory onset to the [Formula: see text] reference was [Formula: see text]79 ms/29 ms for the two algorithms. Our findings also indicate that automatic asynchrony index prediction is reliable. For both algorithms, we found the same deviation of [Formula: see text] to the [Formula: see text]-based reference.ConclusionsOur study demonstrates the feasibility of automating the quantification of patient-ventilator asynchrony in critically ill patients using noninvasive sEMG. This may facilitate more frequent diagnosis of asynchrony and support improving patient-ventilator interaction.
Project description:BackgroundThe end-expiratory occlusion (EEXPO) test detects preload responsiveness, but it is 15 s long and induces small changes in cardiac index (CI). It is doubtful whether the Starling bioreactance device, which averages CI over 24 s and refreshes the displayed value every 4 s (Starling-24.4), can detect the EEXPO-induced changes in CI (ΔCI). Our primary goal was to test whether this Starling device version detects preload responsiveness through EEXPO. We also tested whether shortening the averaging and refresh times to 8 s and one second, respectively, (Starling-8.1) improves the accuracy of the device in detecting preload responsiveness using EEXPO.MethodsIn 42 mechanically ventilated patients, during a 15-s EEXPO, we measured ∆CI through calibrated pulse contour analysis (CIpulse, PiCCO2 device) and using the Starling device. For the latter, we considered both CIStarling-24.4 from the commercial version and CIStarling-8.1 derived from the raw data. For relative ∆CIStarling-24.4 and ∆CIStarling-8.1 during EEXPO, we calculated the area under the receiver operating characteristic curve (AUROC) to detect preload responsiveness, defined as an increase in CIpulse ≥ 10% during passive leg raising (PLR). For both methods, the correlation coefficient vs. ∆CIpulse was calculated.ResultsTwenty-six patients were preload responders and sixteen non preload-responders. The AUROC for ∆CIStarling-24.4 was significantly lower compared to ∆CIStarling-8.1 (0.680 ± 0.086 vs. 0.899 ± 0.049, respectively; p = 0.027). A significant correlation was observed between ∆CIStarling-8.1 and ∆CIpulse (r = 0.42; p = 0.009), but not between ∆CIStarling-24.4 and ∆CIpulse. During PLR, both ∆CIStarling-24.4 and ∆CIStarling-8.1 reliably detected preload responsiveness.ConclusionsShortening the averaging and refresh times of the bioreactance signal to 8 s and one second, respectively, increases the reliability of the Starling device in detection of EEXPO-induced ∆CI.Trial registrationNo.Idrcb2018-A02825-50. Registered 13 December 2018.
Project description:BackgroundCarbon dioxide (CO2) accumulation during prolonged painless colonoscopy procedures in patients with obstructive sleep apnea syndrome (OSAS) can lead to an increased incidence of various complications. The disposable end-expiratory CO2 device monitors the respiratory function and CO2 elimination of patients in real time, providing timely feedback to physicians. This enhances the safety and success of the procedure and improves the overall medical experience for the patient.MethodA total of 158 patients with OSAS underwent colonoscopy and were divided into two groups. The study group received end-expiratory CO2 monitoring, while the control group underwent routine monitoring. Perioperative interventions, patient satisfaction, and postoperative complications were compared between the two groups using a case-control method. All colonoscopic procedures were performed by surgeons.ResultThe study group exhibited a lower incidence of hypoxemia and higher utilization of upper airway ventilation devices, resulting in greater postoperative satisfaction (P = 0.019, P = 0.002, P < 0.001, respectively). Conversely, the control group experienced a higher incidence of postoperative nausea and vomiting as well as abdominal pain and abdominal distension (P = 0.006, P = 0.038, P < 0.012).ConclusionEmploying disposable end-expiratory CO2 monitoring during painless enteroscopic procedures in patients with OSAS reduces the incidence of hypoxemia, enhances postoperative satisfaction, and decreases the incidence of postoperative complications.Trial registration numberChiCTR2400083702; Registration date: April 2024.