The RAD51-FFPE Test; Calibration of a Functional Homologous Recombination Deficiency Test on Diagnostic Endometrial and Ovarian Tumor Blocks.


ABSTRACT: PARP inhibitor (PARPi) sensitivity is related to tumor-specific defects in homologous recombination (HR). Therefore, there is great clinical interest in tests that can rapidly and reliably identify HR deficiency (HRD). Functional HRD tests determine the actual HR status by using the (dis)ability to accumulate RAD51 protein at sites of DNA damage as read-out. In this study, we further improved and calibrated a previously described RAD51-based functional HRD test on 74 diagnostic formalin-fixed paraffin-embedded (FFPE) specimens (RAD51-FFPE test) from endometrial cancer (EC n = 25) and epithelial ovarian cancer (OC n = 49) patients. We established optimal parameters with regard to RAD51 foci cut-off (≥2) and HRD threshold (15%) using matched endometrial and ovarian carcinoma specimens for which HR status had been established using a RAD51-based test that required ex vivo irradiation of fresh tissue (RECAP test). The RAD51-FFPE test detected BRCA deficient tumors with 90% sensitivity and RECAP-HRD tumors with 87% sensitivity, indicating that it is an attractive alternative to DNA-based tests with the potential to be applied in routine diagnostic pathology.

SUBMITTER: van Wijk LM 

PROVIDER: S-EPMC8232577 | biostudies-literature | 2021 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

The RAD51-FFPE Test; Calibration of a Functional Homologous Recombination Deficiency Test on Diagnostic Endometrial and Ovarian Tumor Blocks.

van Wijk Lise M LM   Kramer Claire J H CJH   Vermeulen Sylvia S   Ter Haar Natalja T NT   de Jonge Marthe M MM   Kroep Judith R JR   de Kroon Cor D CD   Gaarenstroom Katja N KN   Vrieling Harry H   Bosse Tjalling T   Vreeswijk Maaike P G MPG  

Cancers 20210615 12


PARP inhibitor (PARPi) sensitivity is related to tumor-specific defects in homologous recombination (HR). Therefore, there is great clinical interest in tests that can rapidly and reliably identify HR deficiency (HRD). Functional HRD tests determine the actual HR status by using the (dis)ability to accumulate RAD51 protein at sites of DNA damage as read-out. In this study, we further improved and calibrated a previously described RAD51-based functional HRD test on 74 diagnostic formalin-fixed pa  ...[more]

Similar Datasets

| S-EPMC10556259 | biostudies-literature
| S-EPMC11780812 | biostudies-literature
| S-EPMC7563931 | biostudies-literature
| S-EPMC8538374 | biostudies-literature
| S-EPMC4518479 | biostudies-literature
| S-EPMC10425726 | biostudies-literature
| S-EPMC8860612 | biostudies-literature
| S-EPMC7650677 | biostudies-literature
| S-EPMC7026096 | biostudies-literature
| S-EPMC8551835 | biostudies-literature