Unknown

Dataset Information

0

Predictors and 3-year outcomes of compromised left circumflex coronary artery after left main crossover stenting.


ABSTRACT:

Background

There are few predictors of decreased fractional flow reserve (FFR) in the left circumflex coronary artery (LCx) after left main (LM) crossover stenting.

Objectives

We aimed to determine the predictors for low FFR at LCx and possible treatment strategies for compromised LCx, together with their long-term outcomes.

Methods

Altogether, 563 patients who met the inclusion criteria were admitted to our hospital from February 2015 to November 2020 with significant distal LM bifurcation lesions. They underwent single-stent crossover percutaneous coronary intervention (PCI) under intravascular ultrasound (IVUS) guidance with further LCx intervention based on the measured FFR.

Results

The patients showed significant angiographic LCx ostial affection post-LM stenting, but only 116 (20.6%) patients had FFR < 0.8. The three-year composite major adverse cardiac events (MACE) rates were comparable between the high and low FFR groups (16.8% vs. 15.5; p = 0.744). In a multivariate analysis, low FFR at the LCx was associated with post-stenting minimal luminal area (MLA) of LCx (odds ratio [OR]: 0.032, p < .001), post-stenting LCx plaque burden (OR: 1.166, p < .001), poststenting LM MLA (OR: 0.821, p = .038), and prestenting LCx MLA (OR: 0.371, p = .044). In the low FFR group, those with compromised LCx managed with drug-eluting balloon had the lowest three-year MACE rate (8.1%), as compared to either those undergoing kissing balloon inflation (KBI) (17.5%) or stenting (20.5%) (p = 0.299).

Conclusion

Unnecessary LCx interventions can be avoided with FFR-guided LCx intervention. Poststenting MLA and plaque burden of the LCx, and main vessel stent length are poststenting predictors of low FFR.

SUBMITTER: Ullah H 

PROVIDER: S-EPMC8495093 | biostudies-literature | 2021 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Predictors and 3-year outcomes of compromised left circumflex coronary artery after left main crossover stenting.

Ullah Hameed H   Elakabawi Karim K   Ke Han H   Ullah Najeeb N   Ullah Habib H   Shah Sardar Ali SA   Khan Hamad Haider HH   Khan Muhammad Asad MA   Guo Ning N   Yuan Zuyi Z  

Clinical cardiology 20210716 10


<h4>Background</h4>There are few predictors of decreased fractional flow reserve (FFR) in the left circumflex coronary artery (LCx) after left main (LM) crossover stenting.<h4>Objectives</h4>We aimed to determine the predictors for low FFR at LCx and possible treatment strategies for compromised LCx, together with their long-term outcomes.<h4>Methods</h4>Altogether, 563 patients who met the inclusion criteria were admitted to our hospital from February 2015 to November 2020 with significant dist  ...[more]

Similar Datasets

| S-EPMC10020166 | biostudies-literature
| S-EPMC6561992 | biostudies-literature
| S-EPMC6686612 | biostudies-literature
| S-EPMC8302782 | biostudies-literature
| S-EPMC8875308 | biostudies-literature
| S-EPMC4275694 | biostudies-literature
| S-EPMC11845396 | biostudies-literature
| S-EPMC5408627 | biostudies-literature
| S-EPMC6200676 | biostudies-literature
| S-EPMC9820924 | biostudies-literature