An ex vivo physiologic and hyperplastic vessel culture model to study intra-arterial stent therapies.


ABSTRACT: Conventional in vitro methods for biological evaluation of intra-arterial devices such as stents fail to accurately predict cytotoxicity and remodeling events. An ex vivo flow-tunable vascular bioreactor system (VesselBRx), comprising intra- and extra-luminal monitoring capabilities, addresses these limitations. VesselBRx mimics the in vivo physiological, hyperplastic, and cytocompatibility events of absorbable magnesium (Mg)-based stents in ex vivo stent-treated porcine and human coronary arteries, with in-situ and real-time monitoring of local stent degradation effects. Unlike conventional, static cell culture, the VesselBRx perfusion system eliminates unphysiologically high intracellular Mg2+ concentrations and localized O2 consumption resulting from stent degradation. Whereas static stented arteries exhibited only 20.1% cell viability and upregulated apoptosis, necrosis, metallic ion, and hypoxia-related gene signatures, stented arteries in VesselBRx showed almost identical cell viability to in vivo rabbit models (~94.0%). Hyperplastic intimal remodeling developed in unstented arteries subjected to low shear stress, but was inhibited by Mg-based stents in VesselBRx, similarly to in vivo. VesselBRx represents a critical advance from the current static culture standard of testing absorbable vascular implants.

SUBMITTER: Wang J 

PROVIDER: S-EPMC9195126 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

An ex vivo physiologic and hyperplastic vessel culture model to study intra-arterial stent therapies.

Wang Juan J   Kural Mehmet H MH   Wu Jonathan J   Leiby Katherine L KL   Mishra Vinayak V   Lysyy Taras T   Li Guangxin G   Luo Jiesi J   Greaney Allison A   Tellides George G   Qyang Yibing Y   Huang Nan N   Niklason Laura E LE  

Biomaterials 20210529


Conventional in vitro methods for biological evaluation of intra-arterial devices such as stents fail to accurately predict cytotoxicity and remodeling events. An ex vivo flow-tunable vascular bioreactor system (VesselBRx), comprising intra- and extra-luminal monitoring capabilities, addresses these limitations. VesselBRx mimics the in vivo physiological, hyperplastic, and cytocompatibility events of absorbable magnesium (Mg)-based stents in ex vivo stent-treated porcine and human coronary arter  ...[more]

Similar Datasets

2021-05-22 | GSE174858 | GEO
| PRJNA731919 | ENA
| S-EPMC5713913 | biostudies-literature
| S-EPMC6027638 | biostudies-literature
| S-EPMC3328761 | biostudies-other
| S-EPMC3700796 | biostudies-other
| S-EPMC6168986 | biostudies-literature
| S-EPMC5546915 | biostudies-other
2018-04-07 | GSE106685 | GEO
| S-EPMC10524727 | biostudies-literature