Unknown

Dataset Information

0

Differences in Prognostic Value of Myocardial Perfusion Single-Photon Emission Computed Tomography Using High-Efficiency Solid-State Detector Between Men and Women in a Large International Multicenter Study.


ABSTRACT:

Background

Semiquantitative assessment of stress myocardial perfusion defect has been shown to have greater prognostic value for prediction of major adverse cardiac events (MACE) in women compared with men in single-center studies with conventional single-photon emission computed tomography (SPECT) cameras. We evaluated sex-specific difference in the prognostic value of automated quantification of ischemic total perfusion defect (ITPD) and the interaction between sex and ITPD using high-efficiency SPECT cameras with solid-state detectors in an international multicenter imaging registry (REFINE SPECT [Registry of Fast Myocardial Perfusion Imaging With Next-Generation SPECT]).

Methods

Rest and exercise or pharmacological stress SPECT myocardial perfusion imaging were performed in 17 833 patients from 5 centers. MACE was defined as the first occurrence of death or myocardial infarction. Total perfusion defect (TPD) at rest, stress, and ejection fraction were quantified automatically by software. ITPD was given by stressTPD-restTPD. Cox proportional hazards model was used to evaluate the association between ITPD versus MACE-free survival and expressed as a hazard ratio.

Results

In 10614 men and 7219 women, with a median follow-up of 4.75 years (interquartile range, 3.7-6.1), there were 1709 MACE. In a multivariable Cox model, after adjusting for revascularization and other confounding variables, ITPD was associated with MACE (hazard ratio, 1.08 [95% CI, 1.05-1.1]; P<0.001). There was an interaction between ITPD and sex (P<0.001); predicted survival for ITPD<5% was worse among men compared to women, whereas survival among women was worse than men for ITPD≥5%, P<0.001.

Conclusions

In the international, multicenter REFINE SPECT registry, moderate and severe ischemia as quantified by ITPD from high-efficiency SPECT is associated with a worse prognosis in women compared with men.

SUBMITTER: Tamarappoo BK 

PROVIDER: S-EPMC9307118 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Differences in Prognostic Value of Myocardial Perfusion Single-Photon Emission Computed Tomography Using High-Efficiency Solid-State Detector Between Men and Women in a Large International Multicenter Study.

Tamarappoo Balaji K BK   Otaki Yuka Y   Sharir Tali T   Hu Lien-Hsin LH   Gransar Heidi H   Einstein Andrew J AJ   Fish Mathews B MB   Ruddy Terrence D TD   Kaufmann Philipp P   Sinusas Albert J AJ   Miller Edward J EJ   Bateman Timothy M TM   Dorbala Sharmila S   Di Carli Marcelo M   Eisenberg Evann E   Liang Joanna X JX   Dey Damini D   Berman Daniel S DS   Slomka Piotr J PJ  

Circulation. Cardiovascular imaging 20220621 6


<h4>Background</h4>Semiquantitative assessment of stress myocardial perfusion defect has been shown to have greater prognostic value for prediction of major adverse cardiac events (MACE) in women compared with men in single-center studies with conventional single-photon emission computed tomography (SPECT) cameras. We evaluated sex-specific difference in the prognostic value of automated quantification of ischemic total perfusion defect (ITPD) and the interaction between sex and ITPD using high-  ...[more]

Similar Datasets

| S-EPMC6693293 | biostudies-literature
| S-EPMC8413887 | biostudies-literature
| S-EPMC11631184 | biostudies-literature
| S-EPMC11210974 | biostudies-literature
| S-EPMC6915825 | biostudies-literature
| S-EPMC5721092 | biostudies-literature
| S-EPMC6434693 | biostudies-literature
| S-EPMC6558785 | biostudies-literature
| S-EPMC6604852 | biostudies-literature
| S-EPMC5819626 | biostudies-other