Comparison of SARS-CoV-2 spike antibody quantitative titer reporting using the World Health Organization International Standard Units by four commercial assays.


ABSTRACT: The accurate measurement of serological response to SARS-CoV-2 vaccination is needed to correlate responses with effective protective immunity. The World Health Organization (WHO) has created an international standard to allow harmonization of immune response assessment to an arbitrary unit across different commercial assays; however, the accuracy of reporting of SARS-CoV-2 spike antibody titers in international standard units (BAU or IU/mL) from commercial assays is not well studied. Here, we report the performance comparison of four quantitative commercial assays testing for SARS-CoV-2 spike immunoglobins using the WHO's international standard. Sera, EDTA-plasma and heparinized plasma collected from individuals who are vaccine naïve or received BNT162b2 (Pfizer/BioNTech), mRNA-1273 (Moderna) or ChAdOx1-S (Oxford-AstraZeneca) were tested using Abbott Architect AdviseDx SARS-CoV-2 IgG II, DiaSorin LIAISON SARS-CoV-2 TrimericS IgG, Roche Elecsys Anti-SARS-CoV-2 S and GenScript cPass SARS-CoV-2 surrogate virus neutralization assays. The sensitivities ranged from 90% to 100%, and specificities from 88% to 100%. These four assays had excellent agreement (0.79-0.93) and correlation (0.87-0.97); however, Passing-Bablok regression analysis indicated that data generated by these assays were not comparable. Our data suggests that natural SARS-CoV-2 infection elicited a greater antibody response compared to vaccines, evident by a significantly higher neutralizing antibody titer in unvaccinated individuals who seroconverted.

SUBMITTER: Zhuo R 

PROVIDER: S-EPMC9444336 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of SARS-CoV-2 spike antibody quantitative titer reporting using the World Health Organization International Standard Units by four commercial assays.

Zhuo Ran R   Charlton Carmen C   Plitt Sabrina S   Thompson L Alexa LA   Braun Sheila S   Day Jacqueline J   Osiowy Carla C   Tipples Graham G   Kanji Jamil N JN  

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology 20220906


The accurate measurement of serological response to SARS-CoV-2 vaccination is needed to correlate responses with effective protective immunity. The World Health Organization (WHO) has created an international standard to allow harmonization of immune response assessment to an arbitrary unit across different commercial assays; however, the accuracy of reporting of SARS-CoV-2 spike antibody titers in international standard units (BAU or IU/mL) from commercial assays is not well studied. Here, we r  ...[more]

Similar Datasets

| S-EPMC8403673 | biostudies-literature
| S-EPMC3647515 | biostudies-literature
| S-EPMC4572535 | biostudies-literature
| S-EPMC5078541 | biostudies-literature
| S-EPMC8700542 | biostudies-literature
| S-EPMC11615724 | biostudies-literature
| S-EPMC6791859 | biostudies-literature
| S-EPMC9603218 | biostudies-literature
| S-EPMC5557192 | biostudies-literature
| S-EPMC4209119 | biostudies-literature