Exceeding the Limits of Static Cold Storage in Limb Transplantation Using Subnormothermic Machine Perfusion.


ABSTRACT:

Background

 For 50 years, static cold storage (SCS) has been the gold standard for solid organ preservation in transplantation. Although logistically convenient, this preservation method presents important constraints in terms of duration and cold ischemia-induced lesions. We aimed to develop a machine perfusion (MP) protocol for recovery of vascularized composite allografts (VCA) after static cold preservation and determine its effects in a rat limb transplantation model.

Methods

 Partial hindlimbs were procured from Lewis rats and subjected to SCS in Histidine-Tryptophan-Ketoglutarate solution for 0, 12, 18, 24, and 48 hours. They were then either transplanted (Txp), subjected to subnormothermic machine perfusion (SNMP) for 3 hours with a modified Steen solution, or to SNM

SUBMITTER: Goutard M 

PROVIDER: S-EPMC10848168 | biostudies-literature | 2023 Jun