Unknown

Dataset Information

0

"Deep" sequencing accuracy and reproducibility using Roche/454 technology for inferring co-receptor usage in HIV-1.


ABSTRACT: Next generation, "deep", sequencing has increasing applications both clinically and in disparate fields of research. This study investigates the accuracy and reproducibility of "deep" sequencing as applied to co-receptor prediction using the V3 loop of Human Immunodeficiency Virus-1. Despite increasing use in HIV co-receptor prediction, the accuracy and reproducibility of deep sequencing technology, and the factors which can affect it, have received only a limited level of investigation. To accomplish this, repeated deep sequencing results were generated using the Roche GS-FLX (454) from a number of sources including a non-homogeneous clinical sample (N = 47 replicates over 18 deep sequencing runs), and a large clinical cohort from the MOTIVATE and A400129 studies (N = 1521). For repeated measurements of a non-homogeneous clinical sample, increasing input copy number both decreased variance in the measured proportion of non-R5 using virus (p<<0.001 and 0.02 for single replicates and triplicates respectively) and increased measured viral diversity (p<0.001; multiple measures). Detection of sequences with a mean abundance less than 1% abundance showed a 2 fold increase in median coefficient of variation (CV) in repeated measurements of a non-homogeneous clinical sample, and a 2.7 fold increase in CV in the MOTIVATE/A400129 dataset compared to sequences with ≥1% abundance. An unexpected source of error included read position, with low accuracy reads occurring more frequently towards the edge of sequencing regions (p<<0.001). Overall, the primary source of variability was sampling error caused by low input copy number/minority species prevalence, though other sources of error including sequence intrinsic, temporal, and read-position related errors were detected.

SUBMITTER: Knapp DJ 

PROVIDER: S-EPMC4069016 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

"Deep" sequencing accuracy and reproducibility using Roche/454 technology for inferring co-receptor usage in HIV-1.

Knapp David J H F DJ   McGovern Rachel A RA   Poon Art F Y AF   Zhong Xiaoyin X   Chan Dennison D   Swenson Luke C LC   Dong Winnie W   Harrigan P Richard PR  

PloS one 20140624 6


Next generation, "deep", sequencing has increasing applications both clinically and in disparate fields of research. This study investigates the accuracy and reproducibility of "deep" sequencing as applied to co-receptor prediction using the V3 loop of Human Immunodeficiency Virus-1. Despite increasing use in HIV co-receptor prediction, the accuracy and reproducibility of deep sequencing technology, and the factors which can affect it, have received only a limited level of investigation. To acco  ...[more]

Similar Datasets

| S-EPMC3179495 | biostudies-literature
| S-EPMC3277595 | biostudies-literature
2009-07-01 | GSE16159 | GEO
| S-EPMC4748696 | biostudies-literature
| S-EPMC5319672 | biostudies-literature
| S-EPMC3194189 | biostudies-literature
| S-EPMC3233632 | biostudies-literature
2009-06-30 | E-GEOD-16159 | biostudies-arrayexpress
2012-06-26 | GSE38886 | GEO
| S-EPMC3128616 | biostudies-literature