Unknown

Dataset Information

0

Evaluation of the MeroRisk Calculator, A User-Friendly Tool to Predict the Risk of Meropenem Target Non-Attainment in Critically Ill Patients.


ABSTRACT:

Background

The MeroRisk-calculator, an easy-to-use tool to determine the risk of meropenem target non-attainment after standard dosing (1000 mg; q8h), uses a patient's creatinine clearance and the minimum inhibitory concentration (MIC) of the pathogen. In clinical practice, however, the MIC is rarely available. The objectives were to evaluate the MeroRisk-calculator and to extend risk assessment by including general pathogen sensitivity data.

Methods

Using a clinical routine dataset (155 patients, 891 samples), a direct data-based evaluation was not feasible. Thus, in step 1, the performance of a pharmacokinetic model was determined for predicting the measured concentrations. In step 2, the PK model was used for a model-based evaluation of the MeroRisk-calculator: risk of target non-attainment was calculated using the PK model and agreement with the MeroRisk-calculator was determined by a visual and statistical (Lin's concordance correlation coefficient (CCC)) analysis for MIC values 0.125-16 mg/L. The MeroRisk-calculator was extended to include risk assessment based on EUCAST-MIC distributions and cumulative-fraction-of-response analysis.

Results

Step 1 showed a negligible bias of the PK model to underpredict concentrations (-0.84 mg/L). Step 2 revealed a high level of agreement between risk of target non-attainment predictions for creatinine clearances >50 mL/min (CCC = 0.990), but considerable deviations for patients <50 mL/min. For 27% of EUCAST-listed pathogens the median cumulative-fraction-of-response for the observed patients receiving standard dosing was < 90%.

Conclusions

The MeroRisk-calculator was successfully evaluated: For patients with maintained renal function it allows a reliable and user-friendly risk assessment. The integration of pathogen-based risk assessment substantially increases the applicability of the tool.

SUBMITTER: Liebchen U 

PROVIDER: S-EPMC8074046 | biostudies-literature | 2021 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of the MeroRisk Calculator, A User-Friendly Tool to Predict the Risk of Meropenem Target Non-Attainment in Critically Ill Patients.

Liebchen Uwe U   Klose Marian M   Paal Michael M   Vogeser Michael M   Zoller Michael M   Schroeder Ines I   Schmitt Lisa L   Huisinga Wilhelm W   Michelet Robin R   Zander Johannes J   Scharf Christina C   Weinelt Ferdinand A FA   Kloft Charlotte C  

Antibiotics (Basel, Switzerland) 20210420 4


<h4>Background</h4>The MeroRisk-calculator, an easy-to-use tool to determine the risk of meropenem target non-attainment after standard dosing (1000 mg; q8h), uses a patient's creatinine clearance and the minimum inhibitory concentration (MIC) of the pathogen. In clinical practice, however, the MIC is rarely available. The objectives were to evaluate the MeroRisk-calculator and to extend risk assessment by including general pathogen sensitivity data.<h4>Methods</h4>Using a clinical routine datas  ...[more]

Similar Datasets

| S-EPMC10376356 | biostudies-literature
| S-EPMC8754504 | biostudies-literature
| S-EPMC9581397 | biostudies-literature
| S-EPMC8234236 | biostudies-literature
| S-EPMC7306030 | biostudies-literature
| S-EPMC8538061 | biostudies-literature
| S-EPMC5651591 | biostudies-literature
| S-EPMC9982780 | biostudies-literature
| S-EPMC10109529 | biostudies-literature
| S-EPMC11573875 | biostudies-literature