Project description:Driveline infections (DLI) are common adverse events in left ventricular assist devices (LVADs), leading to severe complications and readmissions. The study aims to characterize risk factors for DLI readmission 2 years postimplant. This single-center study included 183 LVAD patients (43 HeartMate II [HMII], 29 HeartMate 3 [HM3], 111 HVAD) following hospital discharge between 2013 and 2017. Demographics, clinical parameters, and outcomes were retrospectively analyzed and 12.6% of patients were readmitted for DLI, 14.8% experienced DLI but were treated in the outpatient setting, and 72.7% had no DLI. Mean C-reactive protein (CRP), leukocytes and fibrinogen were higher in patients with DLI readmission (P < .02) than in outpatient DLI and patients without DLI, as early as 60 days before readmission. Freedom from DLI readmission was comparable for HMII and HVAD (98% vs. 87%; HR, 4.52; 95% CI, 0.58-35.02; P = .15) but significantly lower for HM3 (72%; HR, 10.82; 95% CI, 1.26-92.68; P = .03). DLI (HR, 1.001; 95% CI, 0.999-1.002; P = .16) or device type had no effect on mortality. DLI readmission remains a serious problem following LVAD implantation, where CRP, leukocytes, and fibrinogen might serve as risk factors already 60 days before. HM3 patients had a higher risk for DLI readmissions compared to HVAD or HMII, possibly because of device-specific driveline differences.
Project description:BackgroundLeft ventricular assist devices (LVADs) improve survival in patients with end-stage heart failure but are associated with ischemic stroke and intracranial hemorrhage (ICH). The impact of LVAD-associated stroke on transplant candidacy and outcomes has not been characterized.MethodsAdult patients undergoing LVAD implantation at Cleveland Clinic between 2004 to 2021 were reviewed and patients who developed ischemic stroke or ICH were identified. Post-transplant survival analysis was performed between patients with LVAD-associated stroke vs. without.Results917 patients had an LVAD implantation of whom 244 (median age 57, 79% male) underwent subsequent transplant including 25 with prior LVAD-associated stroke. The 1- and 2-year survival after transplant in patients with LVAD-associated stroke were 100% and 95% respectively, compared with 92% and 90% in patients without stroke (p=0.156; p=0.323) Similarly, there was no difference in stroke incidence at 1- and 2 years after transplant between patients with LVAD-associated stroke (4% and 5%) and those without prior stroke (5% and 6%, p = 0.884; p=0.744).ConclusionsIn this single-center retrospective study, patients with LVAD-associated stroke were significantly less likely to undergo heart transplant, but those who underwent heart transplant had similar post-transplant outcomes as patients without history of LVAD-associated stroke. Given the similar outcomes seen in this population, history of LVAD-associated stroke should not be viewed as an absolute contraindication to subsequent heart transplant.
Project description:BackgroundPatients with end-stage heart failure are increasingly being bridged to heart transplant (BTT) with mechanical circulatory support; however the association between a left ventricular assist device (LVAD) BTT strategy and posttransplant renal outcomes is unclear. The aim of this study was to analyze the association of LVAD BTT with the development of posttransplant renal failure using a large national registry.MethodsWe queried the 2009 to 2018 United Network for Organ Sharing registry for all adults undergoing first-time heart or heart-kidney transplantation and stratified patients by use of pretransplant durable LVAD. The primary outcome of interest was posttransplant renal failure, which was evaluated with multivariable logistic regression.ResultsOf 18,307 patients meeting inclusion criteria, 7887 were (43%) and 10,420 were not (57%) BTT with an LVAD. BTT patients had slightly better baseline renal function (estimated glomerular filtration rate, 68.7 vs 65.8 mL/min, P < .001) and were less likely to receive a heart-kidney transplant (2.7% vs 4.8%, P < .001). On multivariable logistic regression, LVAD BTT strategy was not independently associated with posttransplant renal failure (odds ratio, 1.13; 95% confidence interval, 0.86-1.49). Similarly LVAD BTT among patients with preoperative renal dysfunction was not associated with posttransplant renal failure (adjusted odds ratio, 1.40; 95% confidence interval, 0.91-2.18).ConclusionsBTT with an LVAD does not appear to be associated with worse renal outcomes regardless of baseline renal function. Furthermore, an LVAD BTT strategy in patients with chronic kidney disease may enable clinicians to identify candidates suitable for isolated heart transplantation without increasing their risk for posttransplant renal failure.
Project description:Molecular analysis of the effect left ventricular assist device (LVAD) support has on congestive heart failure patients. Keywords = Congestive heart failure, left ventricular assist device, eNOS, gene, dimethylarginine dimethylaminohydrolase Keywords: other
Project description:Driveline infection (DLI) is common after left ventricular assist device (LVAD). Limited data exist on DLI prevention and management. We investigated the impact of standardized driveline care initiatives, specific pathogens, and chronic antibiotic suppression (CAS) on DLI outcomes. 591 LVAD patients were retrospectively categorized based on driveline care initiatives implemented at our institution (2009-2019). Era (E)1: nonstandardized care; E2: standardized driveline care protocol; E3: addition of marking driveline exit site; E4: addition of "no shower" policy. 87(15%) patients developed DLI at a median (IQR) of 403(520) days. S. aureus and P. aeruginosa were the most common pathogens. 31 (36%) of DLI patients required incision and drainage (I&D) and 5 (5.7%) device exchange. P. aeruginosa significantly increased risk for initial I&D (HR 2.7, 95% CI, 1.1-6.3) and recurrent I&D or death (HR 4.2, 95% CI, 1.4-12.5). Initial I&D was associated with a significant increased risk of death (HR 2.92 (1.33-6.44); P = 0.008) when compared to patients who did not develop DLI. Implementation of standardized driveline care protocol (E2) was associated with increased 2-year freedom from DLI compared to nonstandardized care (HR 0.36, 95% CI, 0.2-0.6, P < 0.01). Additional preventive strategies (E3&E4) showed no further reduction in DLI rates. 57(65%) DLI patients received CAS, 44% of them required escalation to intravenous antibiotics and/or I&D. Presence of P. aeruginosa DLI markedly increased risk for I&D or death. Conditional survival of patients progressing to I&D is diminished. Standardized driveline care protocol was associated with a significant reduction in DLI, while additional preventive strategies require further testing.
Project description:ObjectivesDriveline infections are a major complication of ventricular assist device (VAD) therapy. A newly introduced Carbothane driveline has preliminarily demonstrated anti-infective potential against driveline infections. This study aimed to comprehensively assess the anti-biofilm capability of the Carbothane driveline and explore its physicochemical characteristics.MethodsWe assessed the Carbothane driveline against biofilm formation of leading microorganisms causing VAD driveline infections, including Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa and Candida albicans, using novel in vitro biofilm assays mimicking different infection micro-environments. The importance of physicochemical properties of the Carbothane driveline in microorganism-device interactions were analyzed, particularly focusing on the surface chemistry. The role of micro-gaps in driveline tunnels on biofilm migration was also examined.ResultsAll organisms were able to attach to the smooth and velour sections of the Carbothane driveline. Early microbial adherence, at least for S. aureus and S. epidermidis, did not proceed to the formation of mature biofilms in a drip-flow biofilm reactor mimicking the driveline exit site environment. The presence of a driveline tunnel however, promoted staphylococcal biofilm formation on the Carbothane driveline. Physicochemical analysis of the Carbothane driveline revealed surface characteristics that may have contributed to its anti-biofilm activity, such as the aliphatic nature of its surface. The presence of micro-gaps in the tunnel facilitated biofilm migration of the studied bacterial species.ConclusionThis study provides experimental evidence to support the anti-biofilm activity of the Carbothane driveline and uncovered specific physicochemical features that may explain its ability to inhibit biofilm formation.
Project description:There is considerable interest in the use of bacteriophages (phages) to treat Pseudomonas aeruginosa infections associated with left ventricular assist devices (LVADs). These infections are often challenging to manage due to high rates of multidrug resistance and biofilm formation, which could potentially be overcome with the use of phages. We report a case of a 54-year-old man with relapsing multidrug-resistant P. aeruginosa LVAD driveline infection, who was treated with a combination of two lytic antipseudomonal phages administered intravenously and locally. Treatment was combined with LVAD driveline repositioning and systemic antibiotic administration, resulting in a successful outcome with clinical cure and eradication of the targeted bacteria. However, laboratory in vitro models showed that phages alone could not eradicate biofilms but could prevent biofilm formation. Phage-resistant bacterial strains evolved in biofilm models and showed decreased susceptibility to the phages used. Further studies are needed to understand the complexity of phage resistance and the interaction of phages and antibiotics. Our results indicate that the combination of phages, antibiotics, and surgical intervention can have great potential in treating LVAD-associated infections. More than 21 months post-treatment, our patient remains cured of the infection.
Project description:In patients with left ventricular assist device (LVAD), infections and thrombotic events represent severe complications. We investigated device-specific local and systemic inflammation and its impact on cerebrovascular events (CVE) and mortality. In 118 LVAD patients referred for 18F-FDG-PET/CT, metabolic activity of LVAD components, thoracic aortic wall, lymphoid and hematopoietic organs, was quantified and correlated with clinical characteristics, laboratory findings, and outcome. Driveline infection was detected in 92/118 (78%) patients by 18F-FDG-PET/CT. Activity at the driveline entry site was associated with increased signals in aortic wall (r = 0.32, p < 0.001), spleen (r = 0.20, p = 0.03) and bone marrow (r = 0.20, p = 0.03), indicating systemic interactions. Multivariable analysis revealed independent associations of aortic wall activity with activity of spleen (β = 0.43, 95% CI 0.18-0.68, p < 0.001) and driveline entry site (β = 0.04, 95% CI 0.01-0.06, p = 0.001). Twenty-two (19%) patients suffered CVE after PET/CT. In a binary logistic regression analysis metabolic activity at the driveline entry site missed the level of significance as an influencing factor for CVE after adjusting for anticoagulation (OR = 1.16, 95% CI 1-1.33, p = 0.05). Metabolic activity of the subcutaneous driveline (OR = 1.13, 95% CI 1.02-1.24, p = 0.016) emerged as independent risk factor for mortality. Molecular imaging revealed systemic inflammatory interplay between thoracic aorta, hematopoietic organs, and infected device components in LVAD patients, the latter predicting CVE and mortality.
Project description:Obstruction of the LVAD flow path can occur when blood clots or tissue overgrowth form within the inflow cannula, pump body, or outflow graft, and it can lead to thrombus, embolism, and stroke. The goal of this study was to measure the impact of progressive pump inflow obstruction on the pressure and flow dynamics of the LVAD-supported heart using a mock circulatory loop. Pump obstruction (PO) was produced by progressively blocking a fraction of the LVAD inlet area. Pressures, flows, and the midplane velocity field of the LV were measured for three LVAD speeds and six PO levels. Pressure and flow decreased with PO, shifting more of the flow through the aortic valve such that the total flow decreased by 6-11% and decreased the efficiency of the work of the native heart up to 60%. PO restricts diastolic flow through the LVAD, which reduces mitral inflow and decreases the strength and energy of the intraventricular vortices. The changes in flow architecture produced by PO include flow stasis and increased shear, which predispose the system to thromboembolic risk. Analysis of the contributions to external work may enable early detection, which allows time for therapeutic intervention, reducing the likelihood of pump replacement and the risk of complications.