Unknown

Dataset Information

0

Desorption Electrospray Ionization Mass Spectrometry Assay for Label-Free Characterization of SULT2B1b Enzyme Kinetics.


ABSTRACT: The sulfotransferase (SULT) 2B1b, which catalyzes the sulfonation of 3β-hydroxysteroids, has been identified as a potential target for prostate cancer treatment. However, a major limitation for SULT2B1b-targeted drug discovery is the lack of robust assays compatible with high-throughput screening and inconsistency in reported kinetic data. For this reason, we developed a novel label-free assay based on high-throughput (>1 Hz) desorption electrospray ionization mass spectrometry (DESI-MS) for the direct quantitation of the sulfoconjugated product (CV<10 %; <1 ng analyte). The performance of this DESI-based assay was compared against a new fluorometric coupled-enzyme method that we also developed. Both methodologies provided consistent kinetic data for the reaction of SULT2B1b with its major substrates, indicating the affinity trend pregnenolone>DHEA>cholesterol, for both the phospho-mimetic and wild-type SULT2B1b forms. The novel DESI-MS assay developed here is likely generalizable to other drug discovery efforts and is particularly promising for identification of SULT2B1b inhibitors with potential as prostate cancer therapeutics.

SUBMITTER: Kulathunga SC 

PROVIDER: S-EPMC10112463 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Desorption Electrospray Ionization Mass Spectrometry Assay for Label-Free Characterization of SULT2B1b Enzyme Kinetics.

Kulathunga Samadhi C SC   Morato Nicolás M NM   Zhou Qing Q   Cooks R Graham RG   Mesecar Andrew D AD  

ChemMedChem 20220210 9


The sulfotransferase (SULT) 2B1b, which catalyzes the sulfonation of 3β-hydroxysteroids, has been identified as a potential target for prostate cancer treatment. However, a major limitation for SULT2B1b-targeted drug discovery is the lack of robust assays compatible with high-throughput screening and inconsistency in reported kinetic data. For this reason, we developed a novel label-free assay based on high-throughput (>1 Hz) desorption electrospray ionization mass spectrometry (DESI-MS) for the  ...[more]

Similar Datasets

| S-EPMC3176668 | biostudies-literature
| S-EPMC3259225 | biostudies-literature
| S-EPMC5887808 | biostudies-literature
| S-EPMC5156945 | biostudies-literature
| S-EPMC2587601 | biostudies-literature
| S-EPMC6821845 | biostudies-literature
| S-EPMC11293027 | biostudies-literature
| S-EPMC9013061 | biostudies-literature
| S-EPMC3938891 | biostudies-literature