A Projection-Domain Low-Count Quantitative SPECT Method for α-Particle-Emitting Radiopharmaceutical Therapy.


ABSTRACT: Single-photon emission-computed tomography (SPECT) provides a mechanism to estimate regional isotope uptake in lesions and at-risk organs after administration of α-particle-emitting radiopharmaceutical therapies (α-RPTs). However, this estimation task is challenging due to the complex emission spectra, the very low number of detected counts (~20 times lower than in conventional SPECT), the impact of stray-radiation-related noise at these low counts, and the multiple image-degrading processes in SPECT. The conventional reconstruction-based quantification methods are observed to be erroneous for α-RPT SPECT. To address these challenges, we developed a low-count quantitative SPECT (LC-QSPECT) method that directly estimates the regional activity uptake from the projection data (obviating the reconstruction step), compensates for stray-radiation-related noise, and accounts for the radioisotope and SPECT physics, including the isotope spectra, scatter, attenuation, and collimator-detector response, using a Monte Carlo-based approach. The method was validated in the context of 3-D SPECT with 223Ra, a commonly used radionuclide for α-RPT. Validation was performed using both realistic simulation studies, including a virtual clinical trial, and synthetic and 3-D-printed anthropomorphic physical-phantom studies. Across all studies, the LC-QSPECT method yielded reliable regional-uptake estimates and outperformed the conventional ordered subset expectation-maximization (OSEM)-based reconstruction and geometric transfer matrix (GTM)-based post-reconstruction partial-volume compensation methods. Furthermore, the method yielded reliable uptake across different lesion sizes, contrasts, and different levels of intralesion heterogeneity. Additionally, the variance of the estimated uptake approached the Cramér-Rao bound-defined theoretical limit. In conclusion, the proposed LC-QSPECT method demonstrated the ability to perform reliable quantification for α-RPT SPECT.

SUBMITTER: Li Z 

PROVIDER: S-EPMC10191330 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Projection-Domain Low-Count Quantitative SPECT Method for <i>α</i>-Particle-Emitting Radiopharmaceutical Therapy.

Li Zekun Z   Benabdallah Nadia N   Abou Diane S DS   Baumann Brian C BC   Dehdashti Farrokh F   Ballard David H DH   Liu Jonathan J   Jammalamadaka Uday U   Laforest Richard R   Wahl Richard L RL   Thorek Daniel L J DLJ   Jha Abhinav K AK  

IEEE transactions on radiation and plasma medical sciences 20220523 1


Single-photon emission-computed tomography (SPECT) provides a mechanism to estimate regional isotope uptake in lesions and at-risk organs after administration of <i>α</i>-particle-emitting radiopharmaceutical therapies (<i>α</i>-RPTs). However, this estimation task is challenging due to the complex emission spectra, the very low number of detected counts (~20 times lower than in conventional SPECT), the impact of stray-radiation-related noise at these low counts, and the multiple image-degrading  ...[more]

Similar Datasets

| S-EPMC8581409 | biostudies-literature
| S-EPMC11807287 | biostudies-literature
| S-EPMC8557232 | biostudies-literature
| S-EPMC9385894 | biostudies-literature
| S-EPMC9630198 | biostudies-literature
| S-EPMC186639 | biostudies-literature
| S-EPMC9475242 | biostudies-literature
| S-EPMC7475100 | biostudies-literature
| S-EPMC6314989 | biostudies-other
| S-EPMC2582153 | biostudies-literature