Patient-tailored risk assessment of obstructive coronary artery disease using Rubidium-82 PET-based myocardial flow quantification with visual interpretation.


ABSTRACT:

Introduction

Our aim was to estimate the probability of obstructive CAD (oCAD) for an individual patient as a function of the myocardial flow reserve (MFR) measured with Rubidium-82 (Rb-82) PET in patients with a visually normal or abnormal scan.

Materials and methods

We included 1519 consecutive patients without a prior history of CAD referred for rest-stress Rb-82 PET/CT. All images were visually assessed by two experts and classified as normal or abnormal. We estimated the probability of oCAD for visually normal scans and scans with small (5%-10%) or larger defects (> 10%) as function of MFR. The primary endpoint was oCAD on invasive coronary angiography, when available.

Results

1259 scans were classified as normal, 136 with a small defect and 136 with a larger defect. For the normal scans, the probability of oCAD increased exponentially from 1% to 10% when segmental MFR decreased from 2.1 to 1.3. For scans with small defects, the probability increased from 13% to 40% and for larger defects from 45% to > 70% when segmental MFR decreased from 2.1 to 0.7.

Conclusion

Patients with > 10% risk of oCAD can be distinguished from patients with < 10% risk based on visual PET interpretation only. However, there is a strong dependence of MFR on patient's individual risk of oCAD. Hence, combining both visual interpretation and MFR results in a better individual risk assessment which may impact treatment strategy.

SUBMITTER: Koenders SS 

PROVIDER: S-EPMC10558363 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Patient-tailored risk assessment of obstructive coronary artery disease using Rubidium-82 PET-based myocardial flow quantification with visual interpretation.

Koenders S S SS   van Dalen J A JA   Jager P L PL   Mouden M M   Slump C H CH   van Dijk J D JD  

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 20230419 5


<h4>Introduction</h4>Our aim was to estimate the probability of obstructive CAD (oCAD) for an individual patient as a function of the myocardial flow reserve (MFR) measured with Rubidium-82 (Rb-82) PET in patients with a visually normal or abnormal scan.<h4>Materials and methods</h4>We included 1519 consecutive patients without a prior history of CAD referred for rest-stress Rb-82 PET/CT. All images were visually assessed by two experts and classified as normal or abnormal. We estimated the prob  ...[more]

Similar Datasets

| S-EPMC6517358 | biostudies-literature
| S-EPMC8873116 | biostudies-literature
| S-EPMC6151305 | biostudies-literature
| S-EPMC6504625 | biostudies-literature
| S-EPMC6517336 | biostudies-literature
| S-EPMC10682245 | biostudies-literature
| S-EPMC9908793 | biostudies-literature
| S-EPMC9345838 | biostudies-literature
| S-EPMC7176539 | biostudies-literature
| S-EPMC6908549 | biostudies-literature