SLOW: A novel spectral editing method for whole-brain MRSI at ultra high magnetic field.


ABSTRACT:

Purpose

At ultra-high field (UHF), B1 + -inhomogeneities and high specific absorption rate (SAR) of adiabatic slice-selective RF-pulses make spatial resolved spectral-editing extremely challenging with the conventional MEGA-approach. The purpose of the study was to develop a whole-brain resolved spectral-editing MRSI at UHF (UHF, B0  ≥ 7T) within clinical acceptable measurement-time and minimal chemical-shift-displacement-artifacts (CSDA) allowing for simultaneous GABA/Glx-, 2HG-, and PE-editing on a clinical approved 7T-scanner.

Methods

Slice-selective adiabatic refocusing RF-pulses (2π-SSAP) dominate the SAR to the patient in (semi)LASER based MEGA-editing sequences, causing large CSDA and long measurement times to fulfill SAR requirements, even using SAR-minimized GOIA-pulses. Therefore, a novel type of spectral-editing, called SLOW-editing, using two different pairs of phase-compensated chemical-shift selective adiabatic refocusing-pulses (2π-CSAP) with different refocusing bandwidths were investigated to overcome these problems.

Results

Compared to conventional echo-planar spectroscopic imaging (EPSI) and MEGA-editing, SLOW-editing shows robust refocusing and editing performance despite to B1 + -inhomogeneity, and robustness to B0 -inhomogeneities (0.2 ppm ≥ ΔB0  ≥ -0.2 ppm). The narrow bandwidth (∼0.6-0.8 kHz) CSAP reduces the SAR by 92%, RF peak power by 84%, in-excitation slab CSDA by 77%, and has no in-plane CSDA. Furthermore, the CSAP implicitly dephases water, lipid and all the other signals outside of range (≥ 4.6 ppm and ≤1.4 ppm), resulting in additional water and lipid suppression (factors ≥ 1000s) at zero SAR-cost, and no spectral aliasing artifacts.

Conclusion

A new spectral-editing has been developed that is especially suitable for UHF, and was successfully applied for 2HG, GABA+, PE, and Glx-editing within 10 min clinical acceptable measurement time.

SUBMITTER: Weng G 

PROVIDER: S-EPMC9212787 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

SLOW: A novel spectral editing method for whole-brain MRSI at ultra high magnetic field.

Weng Guodong G   Radojewski Piotr P   Sheriff Sulaiman S   Kiefer Claus C   Schucht Philippe P   Wiest Roland R   Maudsley Andrew A AA   Slotboom Johannes J  

Magnetic resonance in medicine 20220328 1


<h4>Purpose</h4>At ultra-high field (UHF), B<sub>1</sub><sup>+</sup> -inhomogeneities and high specific absorption rate (SAR) of adiabatic slice-selective RF-pulses make spatial resolved spectral-editing extremely challenging with the conventional MEGA-approach. The purpose of the study was to develop a whole-brain resolved spectral-editing MRSI at UHF (UHF, B<sub>0</sub>  ≥ 7T) within clinical acceptable measurement-time and minimal chemical-shift-displacement-artifacts (CSDA) allowing for simu  ...[more]

Similar Datasets

| S-EPMC9117667 | biostudies-literature
| S-EPMC10330175 | biostudies-literature
| S-EPMC6563461 | biostudies-literature
| S-EPMC9967573 | biostudies-literature
| S-EPMC7498261 | biostudies-literature
| S-EPMC8323956 | biostudies-literature
| S-EPMC8153707 | biostudies-literature
| S-EPMC4447620 | biostudies-literature
| S-EPMC7614292 | biostudies-literature
| S-EPMC5843524 | biostudies-literature