Single-shot top-down proteomics with capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for identification of nearly 600 Escherichia coli proteoforms


ABSTRACT: Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) has been recognized as an invaluable platform for top-down proteomics. However, the scale of top-down proteomics from CZE-MS/MS is still limited due to the low loading capacity and narrow separation window of CZE. In this work, for the first time we systematically evaluated dynamic pH junction method for focusing of intact proteins during CZE-MS. The optimized dynamic pH junction based CZE-MS/MS system approached 1-µL loading capacity, 90-min separation window and high peak capacity (~280) for separation of Escherichia coli proteome. The results represent the largest loading capacity and the highest peak capacity of CZE for top-down characterization of complex proteomes. About 2,800 proteoform-spectrum matches, nearly 600 proteoforms, and 200 proteins were identified from an Escherichia coli lysate by single-shot CZE-MS/MS with spectrum-level false discovery rate (FDR) less than 1%. The number of proteoforms is over three times higher than that from previous single-shot CZE-MS/MS.

INSTRUMENT(S): Q Exactive

ORGANISM(S): Escherichia Coli

SUBMITTER: Liangliang Sun  

LAB HEAD: Liangliang Sun

PROVIDER: PXD007273 | Pride | 2017-10-30

REPOSITORIES: Pride

altmetric image

Publications

Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms.

Lubeckyj Rachele A RA   McCool Elijah N EN   Shen Xiaojing X   Kou Qiang Q   Liu Xiaowen X   Sun Liangliang L  

Analytical chemistry 20171107 22


Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) has been recognized as an invaluable platform for top-down proteomics. However, the scale of top-down proteomics using CZE-MS/MS is still limited due to the low loading capacity and narrow separation window of CZE. In this work, for the first time we systematically evaluated the dynamic pH junction method for focusing of intact proteins during CZE-MS. The optimized dynamic pH junction-based CZE-MS/MS  ...[more]

Similar Datasets

2023-12-07 | PXD042298 | Pride
2019-06-11 | PXD012247 | Pride
2020-02-17 | PXD017265 | Pride
2023-03-11 | PXD027741 | Pride
2020-05-22 | PXD018248 | Pride
2024-03-20 | PXD046651 | Pride
2023-01-05 | PXD029703 | Pride
2023-12-07 | PXD041357 | Pride
2021-01-29 | PXD021183 | Pride
2020-12-08 | PXD020342 | Pride